G1300
1200W high-power battery chargers with charging outputs from 24V/36A to 60V/20A.


1200W.
Built for the long shift.
The G1300 series scales the charger platform to 1200W for high-current battery charging. With charging outputs up to 60V/20A it charges AGV batteries, LEV packs and other equipment where fast charging directly limits uptime.
High power.
Keeps the fleet moving.
1200W high-power battery chargers with charging outputs from 24V/36A to 60V/20A.

Smart cooling.
Ready for any load.
The temperature-controlled fan spins up automatically as load and heat rise, pushing air through the honeycomb vent grid — so 1200W of continuous output stays cool, quiet and stable.

Set the curve.
Or tune it per pack.
Charging voltage, charging current and charge-end current are all settable over CAN / RS485 — CAN is the default — so one charger can serve a battery family instead of a single pack. The embedded 4-stage (lithium) and 3-stage (lead-acid) curves work out of the box, and the default curve stays programmable for customer-specific batteries.

Charges the fleet.
Stage by stage.
Pre-charge → constant current → constant voltage → shut-off. GREEN's charging curve keeps cells safe through every phase of the charge.

Hard on duty.
Easy to trust.
Continuous-duty charging means a fault must never stop the fleet. The charger and the battery behind it are both monitored — short circuit, over-voltage, over-temperature, battery over-voltage and battery reverse polarity — and the metal enclosure is built for vibration, humidity and temperature swings.
- Short circuit
- Over voltage
- Over temperature
- Battery over voltage
- Battery reverse polarity
Every detail,
spelled out.
- Output
- DC24~60V 1200W max (other outputs customizable under G1300-XXXYYY coding: 20–99V / 10–40A)
- Input
- AC90~264V 50/60Hz 14A
- Charging
- Pre-charge → constant current → constant voltage → cut-off
- Indicator
- Bi-color LED: red = charging, green = charged, red flashing = error; LCD digital panel optional
- Comms
- CAN / RS485 (CAN default); charging parameters — voltage, current, battery type — settable via the CAN port using a PC terminal or the optional LCD panel
- Protection
- Short circuit (shut down output) · Over voltage (110% max. output; per-cell threshold by chemistry) · Over temperature (shut down, auto-recover) · Battery over voltage · Battery reverse polarity (internal relay)
- Operating temp
- -10 ~ +40℃ (refer to the derating curve)
- Safety
- IEC 62368
Key specifications shown — the datasheet carries the full tables.