V1.0Design Calculations3 min readSep 28, 2026

Push-Pull & Full-Bridge Transformer and Output Inductor Calculation

Push-pull symmetry design points, full-bridge sandwich winding, output filter inductor calculation and a 600W full-bridge example

FQA - Transformer and Inductor Design Calculations for Push-Pull and Full-Bridge Topologies

ITransformer Design Calculations

1.1Determining the Design Input Parameters

The following parameters must be defined before design:

  • Input voltage range: ~
  • Output voltage:
  • Maximum output power:
  • Switching frequency:
  • Expected efficiency:

1.2Turns Ratio Calculation (Same for Push-Pull and Full-Bridge)

Considering the maximum duty cycle limit (usually, to reserve dead time), the turns ratio is:

Where is the rectifier diode forward voltage drop; the above formula assumes full-bridge diode rectification on the secondary. Push-pull requires two identical Np windings, while full-bridge needs only one Np

1.3Core Selection and AP-Method Calculation (Same for Push-Pull and Full-Bridge)

Use the Area Product (AP) method for initial core selection:

  • : window utilization factor (0.2 for push-pull due to two primary windings, 0.3 for full-bridge)
  • : maximum flux density swing (0.25T for PC95 material)
  • : current density (400~500 A/cm²)
  • : switching frequency (Hz)

Core material selection: - PC95 ferrite is commonly used for its low high-frequency loss,

1.4Turns Calculation (Same for Push-Pull and Full-Bridge)

Primary turns calculation

Based on the fundamental electromagnetic induction formula U=N*Ae*dBm/dt, the primary turns are determined by:

Where is the effective core cross-section (cm²); the factor 2 corresponds to half a cycle,

Note: the push-pull circuit uses a center-tapped primary; each half winding has Np turns

Secondary turns calculation

1.5Key Points of Winding Design

Push-pull transformer symmetry design

The push-pull topology demands extremely high symmetry between the two primary half-windings:

  • Turns symmetry: turn deviation between the two halves must be <0.5%, otherwise flux imbalance saturation occurs
  • Leakage inductance matching: leakage inductance difference between the two halves must be within 5%

- Flux imbalance suppression measures: 1. Core gap design: introduce an appropriate gap (mm) to increase DC reluctance and improve flux imbalance immunity 2. Series blocking capacitor: add a non-polarized capacitor in the primary loop to block the DC component 3. Current-mode control: cycle-by-cycle current sensing and balancing

Full-bridge transformer design points

Leakage inductance control: leakage in the full-bridge topology helps achieve ZVS

  • Winding structure: sandwich winding is recommended to reduce proximity-effect loss

IIOutput Filter Inductor Design Calculations

2.1Inductance Calculation

The output filter inductor usually takes 20%~30% of the rated current as the ripple current peak-to-peak value.

Critical inductance calculation (based on U=L*dI/dt):

Where is the maximum allowed ripple current, typically:

2.2Core Selection

Ku
0.2~0.4 for iron powder and alloy powder toroids
J
300~400A/cm2 for natural cooling, 400~600 A/cm2 for thermally conductive glue or forced-air cooling
Bmax
0.6~1.2 for iron powder and alloy powder cores; consult the datasheet for specifics

2.3Turns Calculation

Based on the AL value (inductance factor):

2.4Wire Diameter Selection and Loss Calculation

Wire diameter selection:

IIIDesign Example: 600W Full-Bridge DC-DC Converter

3.1Design Specifications

Output voltage: 120V DC

Input voltage: 20V~30V DC

Switching frequency
100kHz
Efficiency target
>90%
Ripple current
<20%

3.2Transformer Design

Turns ratio calculation (taking ):

Core selection:

Select PQ35/30 (, )

Turns calculation (taking ):

3.3Output Inductor Design

Inductance calculation (20% ripple, equivalent frequency 200kHz):

Take .

Core selection:

0.035cm^4

Use a Kool Mμ core KH080-060, Ae=0.22cm^2, AL=32

Turns:

IVTransformer and Inductor Loss Calculations

See 'Electromagnetic Loss Calculation for Power Inductors and Transformers'

Copper loss Pcu= Irms *Irms* Rdc * Fr; skin factor Fr is 1.1~1.5, see the referenced article Core loss Pcore= K*fsa*Bb*Ve, where fs is frequency, B is the flux density change, Ve is the core volume

K, a, b are constants; refer to the manufacturer datasheet. Reference values for the PC95 core:

K=1.5×10⁻⁶、a=1.25、b=2.55

f in kHz, Bac in mT, Ve in cm3, Pcore in mW

Quick estimate (B=0.25, f=80k): Pcore=468*Ve (mW) = 0.47*Ve (W) (B=0.20,f=80k)Pcore=267*Ve (mW ) = 0.27*Ve (W)