Calculate the transformer AP value and select the transformer core bobbin
: area product, (cm⁴)
: input power (W)
: window utilization factor (0.2 recommended for transformers, 0.3 for toroidal inductors)
: waveform factor: sine wave: , square wave:
: operating frequency (Hz)
: maximum operating flux density (T). 0.2~0.3T recommended for ferrite; 1.0 for iron powder cores
: current density (A/cm²). Selected according to temperature rise; 200~400A/cm² recommended.
: unit conversion factor (when and are converted from m² to cm², , but since J uses A/cm² etc., the final factor simplifies to )
For this case, the calculation is as follows:
Input power (W):
Window utilization factor:
Waveform factor:
Operating frequency (Hz):
Maximum operating flux density (T):
Current density (A/cm²):
AP value calculation:
- Actually selected core
- PQ3225, with core parameters:
- The AP value of this core
- , greater than the required 1.28.
Calculate the primary/secondary turns ratio and the primary/secondary winding currents
Determine the Input/Output Parameters
Input PFC voltage parameter:
Input PFC voltage parameter:
Output voltage:
Output current:
Output power:
Preset efficiency:
Input power:
Switching frequency:
Period:
Preset maximum duty cycle:
Reference output diode forward voltage drop:
Turns ratio calculation:
Rounded turns ratio:
Define the ripple factor:
Ripple factor value:
Primary-side average current: 1.9A
Primary peak current:
Primary RMS current:
Secondary peak current:

Secondary RMS current:
Calculate the transformer primary and secondary turns
Selected core model: PQ3225
Ae value of the selected core:
Maximum flux density of the core:
Minimum primary turns:
Minimum secondary turns: 1.5
Rounded secondary turns:
Primary turns calculated from the rounded secondary turns:
Actually chosen primary turns:
Summary of actual primary/secondary turns and turns ratio:
Verify the B value:
Calculate the transformer inductance
- Transformer core material
- PC40
- AL value without gap (unit
- nH/turns²):
For a forward transformer, the larger the inductance the better, as it reduces the magnetizing current; therefore no air gap is needed.
Calculate the transformer inductance
Calculate the transformer wire diameter
Selected current density: , forced-air cooling
Primary RMS current obtained above:
Required wire cross-section:
Selected single-strand diameter:
Calculate the primary strand count: (minimum strands)
Selected current density: , forced-air cooling
Secondary RMS current obtained above:
Required cross-section:
Select the copper foil width:
Copper foil thickness:
Therefore: the primary uses single-strand 0.5mm copper wire, and the secondary uses 10mm-wide, 0.35mm-thick copper foil
Calculate the Transformer Losses
Single wire:
Total cross-section:
Total length:
DC resistance:
AC/DC resistance ratio:
Primary copper loss:
Secondary winding copper loss:
Cross-section:
Total length:
DC resistance:
AC/DC resistance ratio:
Secondary copper loss:
Total transformer copper loss:
fs is the frequency, B is the flux density change, Ve is the effective core volume
fs in kHz, Bac in mT, Ve in cm3, Pcore in mW
For this case, B=218mT, core volume, switching frequency
Therefore: total transformer loss = 0.9+4.7=5.6W
Calculate the output energy-storage inductance and wire diameter
Calculate the minimum duty cycle
The output energy-storage inductor of the forward circuit is calculated from the inductor voltage formula U=L*di/dt and volt-second balance (the voltage-time products across the inductor are equal when the main switch is on and off); we compute using the main-switch-off interval,
U=Vout, di=ripple factor*Iout=0.2*Iout, dt=T_off=(1-D)/f,
Selected current density: , forced-air cooling
Output inductor RMS current:
Required wire cross-section:
Selected single-strand diameter: , cross-section 1.13mm2. Since the DC component of the energy-storage inductor far exceeds the AC component, high-frequency skin effect can be ignored and a large-diameter copper wire can be chosen.
Calculate the strand count: (minimum strands). Since the turns are few and it is air-cooled, 4 parallel wires are sufficient in practice
- Calculate the inductor AP value; select the inductor material, size, wire diameter and turns
Actual energy-storage inductance:
The energy-storage inductor of a forward circuit carries a large DC current component, which equals the output current. Therefore a high-saturation iron powder core or similar toroid must be chosen with Bmax above 1.0T. Here we select a Sendust (Fe-Si-Al) toroid whose saturation flux density Bmax reaches 1.6T
Inductor RMS current:
Inductor peak current:
Bmax is the peak flux density:
Ku is the window factor:
J is the current density; 400-600A/cm2 for forced-air cooling (air-cooled)
AP value:
Selected toroid parameters: T28*14*12MM (OD*ID*H), Sendust
Verify the AP, greater than the required 0.53
Calculate the required minimum turns: dB<=0.25T, from Uout = N*dB*Ae/Toff,
DC Resistance
For this case, B=80mT, core volume, switching frequency